Community
Participate
Working Groups
Build Identifier: cvs HEAD when clicking the horizontal scroll bar thumb (ends up in page up & page down events) the size and positioning calculation in class org.eclipse.nebula.widgets.ganttchart.HorizontalScrollbarHandler does not calculate correctly. You are able to scroll unlimited in the past (ie.to the left) in the gantt chart even if style GanttFlags.H_SCROLL_FIXED_RANGE is set. Reproducible: Always Steps to Reproduce: 1. open GanttTester 2. enable "random event length" on the right ("Fixed H-Scrollbar" is enabled by default) 3. click on Create button 4. scroll all the way to the right by dragging the horizontal scrollbar thumb to the rightmost position 5. scroll to the left by clicking on the horizontal scrollbar "left of the thumb". the size and position of the thumb is incorrect and you can scroll to the left as far as you want. It should stop near the first event in the gantt chart.
Created attachment 200658 [details] bugfix for horizontal scroll issue we made some test with other styles that H_SCROLL_FIXED_RANGE, but correct behavior should be checked
Bug fixed in Nebula 2.3.0 (Patch developped by Peter Hermsdorf applied and tested)
Thanks Laurent! Great that you finally fixed that Bug. Bye Peter
Hi Peter Happy that you enjoyed it ;)