Some Eclipse Foundation services are deprecated, or will be soon. Please ensure you've read this important communication.
Bug 324921 - ROV problems with 28x (sign extend 0x8xxx yields wrong addr)
Summary: ROV problems with 28x (sign extend 0x8xxx yields wrong addr)
Status: CLOSED FIXED
Alias: None
Product: RTSC
Classification: Technology
Component: Rta (show other bugs)
Version: unspecified   Edit
Hardware: All All
: P3 normal (vote)
Target Milestone: ---   Edit
Assignee: Chris McCormick CLA
QA Contact:
URL:
Whiteboard: target:3.20.04
Keywords:
Depends on:
Blocks:
 
Reported: 2010-09-09 23:23 EDT by Karl Wechsler CLA
Modified: 2011-06-20 14:40 EDT (History)
1 user (show)

See Also:


Attachments
slides with summary (226.00 KB, application/powerpoint)
2010-09-09 23:23 EDT, Karl Wechsler CLA
no flags Details

Note You need to log in before you can comment on or make changes to this bug.
Description Karl Wechsler CLA 2010-09-09 23:23:58 EDT
Created attachment 178581 [details]
slides with summary

see attached .ppt

problem can be easily reproduced.  build '28x/task' app for control28027 and load and run on simulator.  You'll see bogus ROV.

Note that the stop-mode RTA views are OK (as seen in the .ppt)
Comment 1 Dave Russo CLA 2010-09-20 15:42:31 EDT
Fixed in xdc-v49 by Chris McCormick
Comment 2 Karl Wechsler CLA 2010-09-20 20:12:52 EDT
installed 3.20.04.67_eng into my CCSv4.2.09025 install and verified that the sign-extend problem is fixed.

however, I did have problem where my "windows->preferences" needed to be updated to find the right version of XDCtools.  It "used to work" and find the right version of XDC based on the project that housed the example.  Now, the Windows->Preferences need to match the project settings.  Bummer.  Chris McC is going to follow up with Toronto on this.
Comment 3 Dave Russo CLA 2011-06-20 14:40:17 EDT
Shipped in XDCtools 3.20.04