Some Eclipse Foundation services are deprecated, or will be soon. Please ensure you've read this important communication.
Bug 313780 - RTA string lookup problem on MSP430
Summary: RTA string lookup problem on MSP430
Status: CLOSED FIXED
Alias: None
Product: RTSC
Classification: Technology
Component: Rta (show other bugs)
Version: unspecified   Edit
Hardware: All All
: P3 normal (vote)
Target Milestone: ---   Edit
Assignee: Chris McCormick CLA
QA Contact:
URL:
Whiteboard:
Keywords:
Depends on:
Blocks:
 
Reported: 2010-05-20 13:21 EDT by Chris McCormick CLA
Modified: 2011-11-09 18:55 EST (History)
1 user (show)

See Also:


Attachments

Note You need to log in before you can comment on or make changes to this bug.
Description Chris McCormick CLA 2010-05-20 13:21:51 EDT
This is the same as Bug 313779 except for RTA. RTA needs to initialize the xdc.rta.Formatter with the target arg size so that it can correctly convert any negative values into unsigned target addresses for string lookup.
Comment 1 Chris McCormick CLA 2010-08-24 19:15:27 EDT
Fixed in rov-c19.
Comment 2 Dave Russo CLA 2011-11-09 18:55:53 EST
closing "ancient" resolved bugs