Some Eclipse Foundation services are deprecated, or will be soon. Please ensure you've read this important communication.
Bug 234887 - TVT34:TCT664: PLK: untranslated strings in "Dimension Builder"
Summary: TVT34:TCT664: PLK: untranslated strings in "Dimension Builder"
Status: RESOLVED FIXED
Alias: None
Product: z_Archived
Classification: Eclipse Foundation
Component: BIRT (show other bugs)
Version: 2.3.0   Edit
Hardware: PC Linux-GTK
: P3 minor (vote)
Target Milestone: 2.3.1   Edit
Assignee: Ning Zhang CLA
QA Contact:
URL: 664
Whiteboard:
Keywords:
Depends on: 237748
Blocks:
  Show dependency tree
 
Reported: 2008-05-30 13:16 EDT by CDE Administration CLA
Modified: 2008-07-10 03:25 EDT (History)
5 users (show)

See Also:


Attachments
4.002710_PLK_0527.jpg (174.12 KB, image/jpeg)
2008-05-30 13:16 EDT, CDE Administration CLA
no flags Details
4.002710_PLK_0611.jpg (16.07 KB, image/jpeg)
2008-06-12 10:17 EDT, CDE Administration CLA
no flags Details

Note You need to log in before you can comment on or make changes to this bug.
Description CDE Administration CLA 2008-05-30 13:16:45 EDT
<response_by> Moravia IT at 2008.05.30.11.57.37 </response_by>
This is tct625 split into parts.

OS: Linux
Build date: 0528
Component/Function name: BIRT
Blocking: NO
Tester Name: Kamil Ignacak

Steps to recreate the problem:
1) Open New Project dialog from Eclipse File menu, expand Business Intelligence and Reporting Tools-> Report Project and click Next.
2) Type any Project name on Report Project name field and click Finish.
Note: Open Associated Perspective dialog is displayed.
3) Click Yes if you are ready to start the test so that Eclipse displayed BIRT perspective.
4) Start Eclipse and change the Perspective to Report Designer from Window->Open Perspective->Other?
5) On Navigator view, right click the project and select Import, select File System, and select the Test_Report_1.rptdesign
and Test_Report_1.properties. Then, click Finish.
6) Double click the Test_Report_1.rptdesign on Navigator view.
Note: The report design is displayed.
7) Click anywhere on the report and select General property.
8) Click CUSTOMNAME text control on the report and select the General Property.
9) Click on the Advanced node in the Property Editor panel

Problem description:
Some items in Advanced tab have values with units (like 0pt in Data -> Box -> Margin Left). When I click on one of the values to edit it, a small button appears that allows me to open "Dimension Builder" dialog window. The problem is that value units in this window are not externalized. I think that they should be, at least "in" (correct me if I'm wrong).

Please see attached screenshot.

Kamil Ignacak

<response_by> Cam-Thu Le at 2008.05.30.12.03.11 </response_by>
Units on Dimension Builder dialog should be externalized.

Thanks,
Doshiro.

<response_by> Cam-Thu Le at 2008.05.30.12.03.20 </response_by>
This article was reassigned from Category:''TVT/Testing,Inbox''.
Comment 1 CDE Administration CLA 2008-05-30 13:16:56 EDT
Created attachment 102908 [details]
4.002710_PLK_0527.jpg
Comment 2 CDE Administration CLA 2008-05-30 13:17:02 EDT
<cde:tctdetail>
Testcase: BIRT/4.002710
Project: WSW34
Component: Xfer - BIRT/Report Designer
Priority: 3
Subject: PLK: untranslated strings in "Dimension Builder"
Article ID: 664
Originator: tctbroadcast@pl.moraviaworldwide.com
</cde:tctdetail>
Comment 3 Zhiqiang Qian CLA 2008-06-10 03:02:37 EDT
The solution is to make the base dialog resizable and the layout can automatically fit the resizing change.
Comment 4 Zhiqiang Qian CLA 2008-06-10 03:03:34 EDT
Wrong operation, please ignore above comment.
Comment 5 CDE Administration CLA 2008-06-12 10:17:46 EDT
<response_by> Moravia IT at 2008.06.12.09.01.21 </response_by>
Hi,

Additional problem in Dimension Builder dialog window is that decimal point is dot instead of comma. It shoudl be comma in Polish build.

Please investigate.
Kamil
Comment 6 CDE Administration CLA 2008-06-12 10:17:48 EDT
Created attachment 104686 [details]
4.002710_PLK_0611.jpg
Comment 7 CDE Administration CLA 2008-06-12 13:12:41 EDT
<response_by> John Ryding at 2008.06.12.11.34.47 </response_by>
This has been deferred. It will be considered for the 3.4.1 service pack.
Comment 8 Zhiqiang Qian CLA 2008-06-26 06:06:05 EDT
Need use localized string in Dimension Builder.
Comment 9 Ning Zhang CLA 2008-07-10 03:25:59 EDT
Changed the texts of the buttons from "unitName" to a localized form "displayName" (Some of the unitnames are still in abbrev. forms. These are returned by model part.);

Changed the property's displayed units. Only the allowed units of a property are displayed and can be selected on this dialog.

Changed the form of the measure data. The displayed measure data is now loccale-dependent.