Some Eclipse Foundation services are deprecated, or will be soon. Please ensure you've read this important communication.

Bug 364812

Summary: [Sequence Diagram] - Part decompositions
Product: [Modeling] Papyrus Reporter: Chokri Mraidha <Chokri.Mraidha>
Component: CoreAssignee: Chokri Mraidha <Chokri.Mraidha>
Status: RESOLVED FIXED QA Contact:
Severity: normal    
Priority: P3 CC: yves.yang
Version: 0.9.0   
Target Milestone: ---   
Hardware: PC   
OS: Windows 7   
Whiteboard:
Attachments:
Description Flags
Bug fix
none
New issue with scrollbar
none
Fix the problem of resizing when the width is less than label and the problem of Scrollbar none

Description Chokri Mraidha CLA 2011-11-25 05:42:15 EST
Current implementation of lifelines representing decompositions does'nt allow their moving (horizontally), resizing and resizing of the lifeline representing the father component. These operations should be allowed.
Comment 1 Yves YANG CLA 2012-04-10 18:20:01 EDT
I cannot find the way to create a Part Decomposition and create a Port a Lifeline, please advice.
Comment 2 Yves YANG CLA 2012-05-02 07:28:15 EDT
Created attachment 214910 [details]
Bug fix
Comment 3 Yves YANG CLA 2012-05-02 07:37:55 EDT
Created attachment 214911 [details]
New issue with scrollbar

I have the problems get noticed: the scrollbar gets displayed in part decomposition creation. So please not commit it. We work on the new fix.
Comment 4 Yves YANG CLA 2012-05-04 08:31:20 EDT
Created attachment 215056 [details]
Fix the problem of resizing when the width is less than label and the problem of Scrollbar
Comment 5 Chokri Mraidha CLA 2012-05-07 11:19:20 EDT
Patch committed on .r8035.