Summary: [SysML Internal Block Diagram] Cannot create non-atomic FlowPort directly on BlockProperty
Product: [Modeling] Papyrus Reporter: Yann Tanguy <yann.tanguy>
Component: CoreAssignee: Yann Tanguy <yann.tanguy>
Status: RESOLVED FIXED QA Contact:
Severity: normal    
Priority: P3    
Version: 0.8.1   
Target Milestone: SR2   
Hardware: PC   
OS: Windows 7   
Whiteboard:

Description Yann Tanguy CLA 2011-10-11 05:23:45 EDT
When a Part is typed by a Block, as a shortcut it is possible to create a new FlowPort on such Block by directly clicking on the part in IBD.
This does not seem to work when the FlowPort to be created is non atomic.
Comment 1 Yann Tanguy CLA 2011-10-11 05:26:11 EDT
Fixed in branch (r5775) and trunk (r5776).
Comment 2 Yann Tanguy CLA 2011-10-11 05:26:27 EDT
(In reply to comment #1)
> Fixed in branch (r5775) and trunk (r5777).