Description
Ivan Furnadjiev
Two questions come to my mind: 1. Do we really need a PREPARE_UI_ROOT phase in RWTLifeCycle#PHASE_ORDER_SUBSEQUENT? 2. Do we need to handle "handleStartupProbeMeasurementResults" separately from "handleMeasurementResults"? Is handleStartupProbeMeasurementResults really needed? Created attachment 202075 [details]
Patch
After discussion with Frank, we agreed to introduce a boolean field ( isStartupProbeMeasurementPerformed ) in the MeasurementOperator that ensure that handleStartupProbeMeasurementResults is executed only once (in PREPARE_UI_ROOT phase of the first request only).
Applied patch to CVS HEAD. Applied patch to v14_Maintenance branch too. |