Some Eclipse Foundation services are deprecated, or will be soon. Please ensure you've read this important communication.

Bug 354064

Summary: Initialization of the Default Connection Profile Store not reliably triggered at ODA runtime
Product: [Tools] Data Tools Reporter: Linda Chan <lchan>
Component: Open Data AccessAssignee: Linda Chan <lchan>
Status: RESOLVED FIXED QA Contact:
Severity: normal    
Priority: P3    
Version: 1.9   
Target Milestone: 1.9.1   
Hardware: PC   
OS: All   
Whiteboard:

Description Linda Chan CLA 2011-08-05 20:26:37 EDT
When first calling the ODA profile framework at runtime in a clean workspace, the default connection profile store (persisted in the connectivity plugin state location) might not be automatically initialized.  If it happens to access a default profile instance that is automatically created during initialization of the default persisted profile store, such as the BIRT SampleDb profile, the profile is not found.
Comment 1 Linda Chan CLA 2011-08-15 23:07:29 EDT
Committed fix to trigger the profile framework initialization when loading a profile from the default profile store file.

DTP Git changes, tagged with v201108060848:
http://git.eclipse.org/c/datatools/org.eclipse.datatools.connectivity.git/commit/?id=7c3d44848353aed8bf299c16f66b6aa031b4a59c