| Summary: | Model with two transitions at the same transition point generates wrong code | ||||||
|---|---|---|---|---|---|---|---|
| Product: | [Modeling] eTrice | Reporter: | Thomas Jung <tj> | ||||
| Component: | Generators | Assignee: | Project Inbox <etrice.generators-inbox> | ||||
| Status: | CLOSED FIXED | QA Contact: | |||||
| Severity: | normal | ||||||
| Priority: | P3 | CC: | hrr | ||||
| Version: | 0.1.0 | Flags: | hrr:
indigo+
|
||||
| Target Milestone: | --- | ||||||
| Hardware: | PC | ||||||
| OS: | Windows 7 | ||||||
| Whiteboard: | 0.1.0 | ||||||
| Attachments: |
|
||||||
- made name generation unique for self transitions - fixed wrong assumption that transition point must not have more than one outgoing transition (e.g. two self transitions) fixed with d0d60994192dea60b8fda36fb2148b42ea558006 closed resolved bug |
Created attachment 197808 [details] test model If a model contains two triggerd transitions at a single transition point with the same port and message but different guards, the codegenrerator generates wrong code.