Some Eclipse Foundation services are deprecated, or will be soon. Please ensure you've read this important communication.

Bug 337215

Summary: UE while working with the embedded database
Product: [Technology] Jubula Reporter: Tim Winselmann <tim.winselmann>
Component: CoreAssignee: Zeb Ford-Reitz <zeb.ford-reitz>
Status: CLOSED FIXED QA Contact: Tim Winselmann <tim.winselmann>
Severity: blocker    
Priority: P1 CC: zeb.ford-reitz
Version: 0.9.0   
Target Milestone: 1.0   
Hardware: PC   
OS: Windows All   
Whiteboard:
Attachments:
Description Flags
The stack trace shown by the UE. none

Description Tim Winselmann CLA 2011-02-15 09:26:29 EST
Created attachment 188996 [details]
The stack trace shown by the UE.

1. Start GUIdancer
2. Connect to the embedded database
3. Import the Samples 5.0 project and the bound_modules_samples 5.0
4. Restart the GUIdancer
5. Connect to the embedded database and open the Samples project
6. Connect to an AUT Agent and start the DVDTool
7. Start the Test Suite 4_DVD_TOOl_FULL_TEST

--> Unexpected Error occurred (attached file: UE.txt)

It was not possible for me to reproduce this behavior with every AUT. But the DVDTool nearly every time throws this UE, so you may have to try this a few times or repeat starting the Test Execution.
Comment 1 Tim Winselmann CLA 2011-02-16 03:08:31 EST
marked as duplicate of a ticket in the Bredex trac-system.
Comment 2 Tim Winselmann CLA 2011-02-16 03:27:24 EST
Bug reopened, because Error does not only appear during the nightly builds.
Comment 3 Tim Winselmann CLA 2011-02-16 03:28:32 EST
(In reply to comment #2)
> Bug reopened, because Error does not only appear during the nightly builds.

Duplicate of Ticket #3592 in the Bredex trac system.
Comment 5 Tim Winselmann CLA 2011-02-17 07:18:42 EST
No UE anymore.