Some Eclipse Foundation services are deprecated, or will be soon. Please ensure you've read this important communication.

Bug 324921

Summary: ROV problems with 28x (sign extend 0x8xxx yields wrong addr)
Product: [Technology] RTSC Reporter: Karl Wechsler <karl>
Component: RtaAssignee: Chris McCormick <c-mccormick>
Status: CLOSED FIXED QA Contact:
Severity: normal    
Priority: P3 CC: d-russo
Version: unspecified   
Target Milestone: ---   
Hardware: All   
OS: All   
Whiteboard: target:3.20.04
Attachments:
Description Flags
slides with summary none

Description Karl Wechsler CLA 2010-09-09 23:23:58 EDT
Created attachment 178581 [details]
slides with summary

see attached .ppt

problem can be easily reproduced.  build '28x/task' app for control28027 and load and run on simulator.  You'll see bogus ROV.

Note that the stop-mode RTA views are OK (as seen in the .ppt)
Comment 1 Dave Russo CLA 2010-09-20 15:42:31 EDT
Fixed in xdc-v49 by Chris McCormick
Comment 2 Karl Wechsler CLA 2010-09-20 20:12:52 EDT
installed 3.20.04.67_eng into my CCSv4.2.09025 install and verified that the sign-extend problem is fixed.

however, I did have problem where my "windows->preferences" needed to be updated to find the right version of XDCtools.  It "used to work" and find the right version of XDC based on the project that housed the example.  Now, the Windows->Preferences need to match the project settings.  Bummer.  Chris McC is going to follow up with Toronto on this.
Comment 3 Dave Russo CLA 2011-06-20 14:40:17 EDT
Shipped in XDCtools 3.20.04