| Summary: | Cannot open files outside of remote projects from Remote Type/Call Hierarchy view | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Product: | [Tools] PTP | Reporter: | Vivian Kong <vivkong> | ||||||
| Component: | RDT | Assignee: | Vivian Kong <vivkong> | ||||||
| Status: | RESOLVED FIXED | QA Contact: | |||||||
| Severity: | normal | ||||||||
| Priority: | P3 | ||||||||
| Version: | 4.0 | ||||||||
| Target Milestone: | 4.0 | ||||||||
| Hardware: | PC | ||||||||
| OS: | Windows XP | ||||||||
| Whiteboard: | |||||||||
| Attachments: |
|
||||||||
|
Description
Vivian Kong
Created attachment 171166 [details]
proposed patch
Remote Type/Call Hierarchy creates an editor input using a RDT CProject (which does not know of the CModel). A working copy is then created from the editor input and the CreateWorkingCopyOperation requires CModel information and this fails. The editor input should be created using a CDT CProject instead.
Fixed in HEAD. Created attachment 171177 [details]
additional change
|